Agilent Technologies, Inc. 13 SATA PHY, TSG & OOB Test MOI v.1.1 Revision 1.4
Test Procedure:
This parameter is covered by Agilent Technologies, Inc. N5411B automated SATA compliance software,
revision 1.02 or later. Either “PASS” or “FAIL” is shown for the unit interval test in the report generated
at the completion of the testing. Both Min and Max tests must pass to pass the unit interval test.
Observable Results:
• PHY-01a - Mean Unit Interval measured between 666.4333ps (min) to 670.2333ps (max) (for products
running at 1.5Gb/s)
• PHY-01b - Mean Unit Interval measured between 333.2167ps (min) to 335.1167ps (max) (for products
running at 3Gb/s)
• PHY-01c – Mean Unit Interval measured between 166.6083ps (min) to 167.5583ps (max) (for products
running at 6Gb/s)
• The values above shall be based on at least 100,000 UIs (covers at least one SSC profile)
Possible Problems:
Some products may not support disconnect during the process of enabling BIST and testing. For these
products, refer to the Disconnect sections of reference [5] for setup requirement.